Contributions:TBSIStimulator
Synopsis
The TBSIStimulatorFilter interacts with TBSI's USB-SPI wireless stimulator and dongle. The TBSI stimulator and dongle work in conjunction to administer pulses to different output channels on the stimulator. The type of pulses and interval at which these pulses are administered is customizable via the filters parameters.
To use this filter, a TBSI dongle must be connected to the computer via USB and the stimulator must be within range and charged.
Location
http://www.bci2000.org/svn/trunk/src/private/SignalProcessing/TBSIStimulator
Versioning
Authors
Yichuan Wang, Alex Belsten
Source Code Revisions
- Initial development: 5799
- Tested under: 5799
- Known to compile under: 5799
- Broken since: --
Parameters
StimPattern
This is a encoded string that represents the type of pulse that is going to be administered. Currently, encoded strings obtained from TBSI's StimWare software are the only way to change the pulse. To set set a custom pulse,
1. Install TBSI Stimware (install LabView if needed)
2. Go to Stimware installation directory and search for "Dongle.ini"
3. Open "Dongle.ini", change the value "Verbosity" from 0 to 1.
4. Play with various button and observe the SPI command exchange happening in the bottom window.
5. Copy the exact SPI message from the Stimware's bottom window into TBSIStimulator StimPattern parameter if you want to perform that exact same action.