PreRunDuration

The duration of the pause preceding the first trial. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.

PreFeedbackDuration

The duration of target display before feedback begins. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.

FeedbackDuration

The mean duration of feedback. This parameter is not a hard limit to feedback duration but determines cursor speed such that, for a normalized control signal, feedback trials will have this duration on average. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.

PostFeedbackDuration

The duration of result display after feedback. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.

ITIDuration

The duration of the inter-trial interval. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.

MinRunLength

The duration of a run, i.e. the time corresponding to a continuously recorded data file. A run will not stop during a trial, so its actual length may be larger than this value by the length of a trial. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.

NumberTargets

The number of targets on the feedback screen.