- Run src/contrib./Tools/P300GUI/P300_GUI.m
- Close the Editor window that appears, and type in P300_GUI
- A GUI such as the one to the right will appear
- In the upper left-hand column, click on Select Training Data
- Select the data files collected from the runs for THE, QUICK, BROWN, and FOX
- In the lower left-hand column, press the Generate Feature Weights button
- A pair of graphs should be displayed, similar to those below.
- The important feature is to notice that the red line in the upper graph, the accuracy, increases with more flashes
- Close the window of the graphs
- In the lower-middle column, type Training for File Prefix:, and 1 for File #s to Save
- Click on *.prm (v2)
- This will generate a .prm (parameter) file in the same folder as the data files
- Returning to BCI2000, click on Config and Load Parameters, selecting the new .prm file
- In the Application tab, change TextToSpell to JUMPS, and click Set Config
- Press Start to collect one more run of data
- Once the last run of data has finished, go back to the P300_GUI program and click Add Test Data in the upper right-hand column
- Select the newest set of data, and click Apply Feature Weights in the lower right-hand column - A new window of graphs will appear
- The important thing to see from these graphs is where the red line in the upper graph reaches 100%.
- In the example below, this is from 9 to 11, and then drops. This means that 10 flashes gives the best accuracy.
- If this does not give an acceptable level of accuracy, (typically 95% or higher), repeat more test runs to collect more data files. Add these data files as above, and click Apply Feature Weights in the lower right-hand column to look for how many flashes is needed. Repeat as necessary.
- In the lower middle column, type Trained for File Prefix and 1 for File #s to Save
- Click *.prm (v2) again to generate a Trained parameter file
- Close BCI2000, MatLab, and the P300_GUI programs
- Open BCI2000 with the batch\P3Speller_<Your_Amplifier>.bat file
- Click on Config, and Load Parameters
- Load the base parameter file for your amplifier, and then the Trained parameter file.
- In the Filtering tab, set EpochsToAverage to the ideal number found by how many flashes were needed to attain maximum accuracy. In our example, this would be 10.
- In the Application tab:
- NumberOfSequences to this number as well
- Delete the contents of the Text to Spell field
- Set InterpretMode → online free mode
- Make sure the DisplayResults box is checked
- Click Save Parameters and name as you see fit. Typically this parameter file would be P300_<Your Amplifier>_<Volunteer's Intials>_Free_Spelling.prm This file is now the file used for that volunteer in later P300 Spelling sessions
To continue onto performing P300 spelling experiments, continue to Performing a P300 Spelling Session.