Jump to content

Contributions:RDAClientADC: Difference between revisions

From BCI2000 Wiki
Mellinger (talk | contribs)
No edit summary
 
Mellinger (talk | contribs)
No edit summary
Line 31: Line 31:
==States==
==States==
None.
None.
==<tt>getparams</tt> Tool==
<tt>getparams</tt> is a command line utility that allows to obtain appropriate source module parameters from a host running BrainAmp's VisionRecorder.
On the target host, start the VisionRecorder program, check that RDA is enabled under Configuration->Preferences, and click the monitor (eye) button before running <tt>getparams</tt> with the host's IP address as the only parameter (when omitted, this defaults to ''localhost'').
To direct the output into a file that can later be loaded into the operator module's configuration dialog, append a redirection to the command:
getparams localhost > myparamfile.prm

Revision as of 16:30, 13 December 2007

Synopsis

A source component that interfaces to BrainAmp EEG systems, using the TCP/IP-based BrainAmp RDA interface.

Location

http://www.bci2000.org/svn/trunk/src/contrib/SignalSource/RDAClient

Versioning

Authors

juergen.mellinger@uni-tuebingen.de, thomas.schreiner@tuebingen.mpg.de

Version History

Feb 12, 2003: Initial version. Aug 29, 2007: Support for the RDA float protocol (Thomas Schreiner).

Source Code Revisions

  • Initial development: 156
  • Tested under: 1537
  • Known to compile under: 1537
  • Broken since: --

Parameters

SourceCh

The number of digitized and stored channels. This must match the setting in the VisionRecorder program, increased by 1 to account for an additional channel to hold marker information.

SampleBlockSize

The number of samples transmitted at a time. The VisionRecorder appears to send one block each 40ms, so SampleBlockSize should match SamplingRate x 40ms.

SamplingRate

The sampling rate as configured in the VisionRecorder program.

HostName

IP address or name of the host to connect to, typically localhost.

States

None.

getparams Tool

getparams is a command line utility that allows to obtain appropriate source module parameters from a host running BrainAmp's VisionRecorder.

On the target host, start the VisionRecorder program, check that RDA is enabled under Configuration->Preferences, and click the monitor (eye) button before running getparams with the host's IP address as the only parameter (when omitted, this defaults to localhost).

To direct the output into a file that can later be loaded into the operator module's configuration dialog, append a redirection to the command:

getparams localhost > myparamfile.prm