<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://www.bci2000.org/mediawiki/index.php?action=history&amp;feed=atom&amp;title=Contributions%3ARemoteBIC</id>
	<title>Contributions:RemoteBIC - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://www.bci2000.org/mediawiki/index.php?action=history&amp;feed=atom&amp;title=Contributions%3ARemoteBIC"/>
	<link rel="alternate" type="text/html" href="https://www.bci2000.org/mediawiki/index.php?title=Contributions:RemoteBIC&amp;action=history"/>
	<updated>2026-11-22T12:42:51Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.9</generator>
	<entry>
		<id>https://www.bci2000.org/mediawiki/index.php?title=Contributions:RemoteBIC&amp;diff=12703&amp;oldid=prev</id>
		<title>Nluczak: /* Step 2: Configure the Server Computer */</title>
		<link rel="alternate" type="text/html" href="https://www.bci2000.org/mediawiki/index.php?title=Contributions:RemoteBIC&amp;diff=12703&amp;oldid=prev"/>
		<updated>2026-11-20T20:02:53Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;Step 2: Configure the Server Computer&lt;/span&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 20:02, 20 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l254&quot;&gt;Line 254:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 254:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;# Install the BIC RPC server on the server computer and plug the external unit into it.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;# Install the BIC RPC server on the server computer and plug the external unit into it.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;# In &amp;lt;code&amp;gt;config.json&amp;lt;/code&amp;gt;, set &amp;lt;code&amp;gt;address&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;0.0.0.0&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;port&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;50051&amp;lt;/code&amp;gt;. With &amp;lt;code&amp;gt;127.0.0.1&amp;lt;/code&amp;gt; the server would refuse connections from other computers.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;# In &amp;lt;code&amp;gt;config.json&amp;lt;/code&amp;gt;, set &amp;lt;code&amp;gt;address&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;0.0.0.0&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;port&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;50051&amp;lt;/code&amp;gt;. With &amp;lt;code&amp;gt;127.0.0.1&amp;lt;/code&amp;gt; the server would refuse connections from other computers.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;# &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Allow &lt;/del&gt;the server through the Windows firewall. &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Open &lt;/del&gt;PowerShell with &#039;&#039;Run as administrator&#039;&#039; and run:&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;# &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;It may be necessary to allow &lt;/ins&gt;the server through the Windows firewall. &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;If this is an issue you run into, open &lt;/ins&gt;PowerShell with &#039;&#039;Run as administrator&#039;&#039; and run:&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;pre&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;pre&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;New-NetFirewallRule -DisplayName &amp;quot;bicRpcServer&amp;quot; -Direction Inbound -Action Allow -Protocol TCP -LocalPort 50051 -Program &amp;quot;C:\Program Files\Cortec\bicRpcServer-setup\bicRpcServer.exe&amp;quot; -Profile Any&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;New-NetFirewallRule -DisplayName &amp;quot;bicRpcServer&amp;quot; -Direction Inbound -Action Allow -Protocol TCP -LocalPort 50051 -Program &amp;quot;C:\Program Files\Cortec\bicRpcServer-setup\bicRpcServer.exe&amp;quot; -Profile Any&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key wikidb-bci_:diff:1.41:old-12702:rev-12703:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Nluczak</name></author>
	</entry>
	<entry>
		<id>https://www.bci2000.org/mediawiki/index.php?title=Contributions:RemoteBIC&amp;diff=12702&amp;oldid=prev</id>
		<title>Nluczak: Added RemoteBIC documentation</title>
		<link rel="alternate" type="text/html" href="https://www.bci2000.org/mediawiki/index.php?title=Contributions:RemoteBIC&amp;diff=12702&amp;oldid=prev"/>
		<updated>2026-11-20T20:01:53Z</updated>

		<summary type="html">&lt;p&gt;Added RemoteBIC documentation&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;RemoteBICSource is a source module that records from and stimulates through the CorTec Brain Interchange (BIC) implant over a network connection. Instead of talking to the hardware directly, as [[Contributions:CortecADC|CortecADC]] does, BCI2000 connects to the CorTec &amp;#039;&amp;#039;&amp;#039;BIC RPC server&amp;#039;&amp;#039;&amp;#039; (&amp;lt;code&amp;gt;bicRpcServer.exe&amp;lt;/code&amp;gt;), which owns the USB connection to the implant. The server and BCI2000 can run on the same computer or on two computers joined by a router.&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;This page is a step-by-step tutorial.&amp;#039;&amp;#039;&amp;#039; It covers configuring the server, connecting BCI2000 to it, streaming data, and running the server and BCI2000 on separate computers. For the meaning of the individual stimulation parameters and implant states, refer to the [[Contributions:CortecADC|CortecADC]] page.&lt;br /&gt;
&lt;br /&gt;
==Versioning==&lt;br /&gt;
===Authors===&lt;br /&gt;
* Nicholas Luczak (luczak@neurotechcenter.org)&lt;br /&gt;
&lt;br /&gt;
===Tested With===&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; style=&amp;quot;text-align: center;&amp;quot;&lt;br /&gt;
! Component !! Version&lt;br /&gt;
|-&lt;br /&gt;
!BIC RPC server&lt;br /&gt;
|style=&amp;quot;border-left: solid 1px grey;&amp;quot;|&amp;lt;code&amp;gt;bicRpcServer.exe&amp;lt;/code&amp;gt;, build of 11/20/2025&lt;br /&gt;
|-&lt;br /&gt;
!Implant firmware&lt;br /&gt;
|style=&amp;quot;border-left: solid 1px grey;&amp;quot;|1.0.260&lt;br /&gt;
|-&lt;br /&gt;
!Operating system&lt;br /&gt;
|style=&amp;quot;border-left: solid 1px grey;&amp;quot;|Windows 11, 64 bit&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
===Known Issues===&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;No encryption.&amp;#039;&amp;#039;&amp;#039; RemoteBICSource opens an unencrypted gRPC channel. The server&amp;#039;s &amp;lt;code&amp;gt;enableSsl&amp;lt;/code&amp;gt; setting must stay &amp;lt;code&amp;gt;false&amp;lt;/code&amp;gt;, and the connection should only be used on a private, isolated network.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Volatile stimulation is not available.&amp;#039;&amp;#039;&amp;#039; Only the Persistent Command and Persistent Functions stimulation modes work through the server.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;64-bit Windows only.&amp;#039;&amp;#039;&amp;#039; The module is not built on other platforms.&lt;br /&gt;
* Lost samples are marked in the &amp;lt;code&amp;gt;ImplantLostSample&amp;lt;/code&amp;gt; stream and filled with the following valid sample. Handle them in offline analysis as described on the [[Contributions:CortecADC#Known Issues|CortecADC]] page.&lt;br /&gt;
&lt;br /&gt;
==Overview==&lt;br /&gt;
Three pieces are involved. The implant and its external unit are the hardware. The BIC RPC server is a CorTec program that opens the hardware and offers it on a TCP port. RemoteBICSource is the BCI2000 source module that connects to that port.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 Implant  &amp;lt;-- RF --&amp;gt;  Head piece / external unit&lt;br /&gt;
                              |&lt;br /&gt;
                             USB&lt;br /&gt;
                              |&lt;br /&gt;
                +---------------------------+              +---------------------------+&lt;br /&gt;
                |  Server computer          |   gRPC/TCP   |  BCI2000 computer         |&lt;br /&gt;
                |  bicRpcServer.exe         | &amp;lt;----------&amp;gt; |  RemoteBICSource.exe      |&lt;br /&gt;
                |  listens on port 50051    |  port 50051  |  ConnectionAddress        |&lt;br /&gt;
                +---------------------------+              +---------------------------+&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
When both programs run on one computer, the two boxes are the same machine and BCI2000 connects to &amp;lt;code&amp;gt;localhost:50051&amp;lt;/code&amp;gt;. This is the default, and it is the setup described first.&lt;br /&gt;
&lt;br /&gt;
==Starting Point==&lt;br /&gt;
This tutorial assumes the following:&lt;br /&gt;
* The BIC RPC server is installed in &amp;lt;code&amp;gt;C:\Program Files\Cortec\bicRpcServer-setup&amp;lt;/code&amp;gt;.&lt;br /&gt;
* BCI2000 is installed in &amp;lt;code&amp;gt;C:\BCI2000&amp;lt;/code&amp;gt;.&lt;br /&gt;
* The external unit is plugged into a USB port, the head piece sits over the implant, and the implant runs a current firmware version.&lt;br /&gt;
&lt;br /&gt;
Check two things before continuing:&lt;br /&gt;
# &amp;#039;&amp;#039;&amp;#039;The source module exists.&amp;#039;&amp;#039;&amp;#039; Look for &amp;lt;code&amp;gt;C:\BCI2000\prog\RemoteBICSource.exe&amp;lt;/code&amp;gt;. If it is missing, BCI2000 was built without it. The module&amp;#039;s source code is in &amp;lt;code&amp;gt;BCI2000/src/private/SignalSource/RemoteBIC&amp;lt;/code&amp;gt;. Enable the CMake option &amp;lt;code&amp;gt;BUILD_REMOTEBIC_SOURCE&amp;lt;/code&amp;gt; and rebuild; the build downloads the gRPC libraries it needs, and copies the batch files and &amp;lt;code&amp;gt;RemoteBIC.prm&amp;lt;/code&amp;gt; from that folder into &amp;lt;code&amp;gt;batch&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;parms/fragments/amplifiers&amp;lt;/code&amp;gt;.&lt;br /&gt;
# &amp;#039;&amp;#039;&amp;#039;Nothing else is using the implant.&amp;#039;&amp;#039;&amp;#039; Close the CorTec BIC application and any BCI2000 instance running CortecADC. Only one program can open the external unit at a time.&lt;br /&gt;
&lt;br /&gt;
==Configuring the Server==&lt;br /&gt;
===The Server Folder===&lt;br /&gt;
The server folder contains these files:&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! File !! Purpose&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;bicRpcServer.exe&amp;lt;/code&amp;gt;&lt;br /&gt;
|The server program&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;config.json&amp;lt;/code&amp;gt;&lt;br /&gt;
|Server settings: address, port, encryption, compression, logging&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;bicapi.dll&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;ftd2xx.dll&amp;lt;/code&amp;gt;&lt;br /&gt;
|CorTec API and USB driver library used to reach the external unit&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;RemoteBIC.proto&amp;lt;/code&amp;gt;&lt;br /&gt;
|Definition of the network interface. BCI2000 is built against the same file.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;session_logger.text&amp;lt;/code&amp;gt;&lt;br /&gt;
|Text log of the requests the server receives. Written while the server runs.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;test.log&amp;lt;/code&amp;gt;&lt;br /&gt;
|Binary CorTec log of the communication with the implant. Written while the server runs, and it grows quickly.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;config\selfTestConfigs&amp;lt;/code&amp;gt;&lt;br /&gt;
|Configurations for the implant self-tests&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
===Editing config.json===&lt;br /&gt;
Open &amp;lt;code&amp;gt;config.json&amp;lt;/code&amp;gt; in a text editor. Editing files under &amp;#039;&amp;#039;Program Files&amp;#039;&amp;#039; requires an editor started with &amp;#039;&amp;#039;Run as administrator&amp;#039;&amp;#039;. The default file looks like this:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
{&lt;br /&gt;
    &amp;quot;root&amp;quot;: {&lt;br /&gt;
        &amp;quot;serverAddress&amp;quot;: {&lt;br /&gt;
            &amp;quot;address&amp;quot;: &amp;quot;0.0.0.0&amp;quot;,&lt;br /&gt;
            &amp;quot;port&amp;quot;: &amp;quot;50051&amp;quot;&lt;br /&gt;
        },&lt;br /&gt;
        &amp;quot;serverAuthentication&amp;quot;: {&lt;br /&gt;
            &amp;quot;enableSsl&amp;quot;: &amp;quot;false&amp;quot;,&lt;br /&gt;
            &amp;quot;serverKeyPath&amp;quot;: &amp;quot;none&amp;quot;,&lt;br /&gt;
            &amp;quot;serverCertificatePath&amp;quot;: &amp;quot;none&amp;quot;,&lt;br /&gt;
            &amp;quot;rootcertificatePath&amp;quot;: &amp;quot;none&amp;quot;&lt;br /&gt;
        },&lt;br /&gt;
        &amp;quot;serverCompression&amp;quot;: {&lt;br /&gt;
            &amp;quot;enableCompression&amp;quot;: &amp;quot;false&amp;quot;,&lt;br /&gt;
            &amp;quot;compressionLevel&amp;quot;: &amp;quot;0&amp;quot;&lt;br /&gt;
        },&lt;br /&gt;
        &amp;quot;serverLogging&amp;quot;: {&lt;br /&gt;
            &amp;quot;enableLogging&amp;quot;: &amp;quot;true&amp;quot;&lt;br /&gt;
        }&lt;br /&gt;
    }&lt;br /&gt;
}&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Setting !! Value to use !! Explanation&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;serverAddress.address&amp;lt;/code&amp;gt;&lt;br /&gt;
|&amp;lt;code&amp;gt;0.0.0.0&amp;lt;/code&amp;gt;&lt;br /&gt;
|The network interface the server listens on. &amp;lt;code&amp;gt;0.0.0.0&amp;lt;/code&amp;gt; means all interfaces, so the server is reachable both locally and from other computers. Use &amp;lt;code&amp;gt;127.0.0.1&amp;lt;/code&amp;gt; to accept connections from the same computer only.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;serverAddress.port&amp;lt;/code&amp;gt;&lt;br /&gt;
|&amp;lt;code&amp;gt;50051&amp;lt;/code&amp;gt;&lt;br /&gt;
|The TCP port. It must match the port in the BCI2000 &amp;lt;code&amp;gt;ConnectionAddress&amp;lt;/code&amp;gt; parameter.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;serverAuthentication.enableSsl&amp;lt;/code&amp;gt;&lt;br /&gt;
|&amp;lt;code&amp;gt;false&amp;lt;/code&amp;gt;&lt;br /&gt;
|&amp;#039;&amp;#039;&amp;#039;Must be &amp;lt;code&amp;gt;false&amp;lt;/code&amp;gt;.&amp;#039;&amp;#039;&amp;#039; RemoteBICSource does not support encrypted connections. Leave the three path settings at &amp;lt;code&amp;gt;none&amp;lt;/code&amp;gt;.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;serverCompression.enableCompression&amp;lt;/code&amp;gt;&lt;br /&gt;
|&amp;lt;code&amp;gt;false&amp;lt;/code&amp;gt;&lt;br /&gt;
|Leave compression off.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;serverLogging.enableLogging&amp;lt;/code&amp;gt;&lt;br /&gt;
|&amp;lt;code&amp;gt;true&amp;lt;/code&amp;gt;&lt;br /&gt;
|Keeps &amp;lt;code&amp;gt;session_logger.text&amp;lt;/code&amp;gt; up to date, which is the easiest way to see whether BCI2000 is reaching the server.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
All values are written as quoted strings, including the port and the true/false settings. Keep the quotes.&lt;br /&gt;
&lt;br /&gt;
===Allowing the Server to Write its Logs===&lt;br /&gt;
The server writes &amp;lt;code&amp;gt;session_logger.text&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;test.log&amp;lt;/code&amp;gt; into its own folder. Standard users cannot write to &amp;#039;&amp;#039;Program Files&amp;#039;&amp;#039;, so do one of the following:&lt;br /&gt;
* Start the server with &amp;#039;&amp;#039;Run as administrator&amp;#039;&amp;#039;, or&lt;br /&gt;
* Give your user account &amp;#039;&amp;#039;Modify&amp;#039;&amp;#039; permission on the server folder: right-click the folder, choose &amp;#039;&amp;#039;Properties → Security → Edit&amp;#039;&amp;#039;, select your user, and tick &amp;#039;&amp;#039;Modify&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
===Starting the Server===&lt;br /&gt;
# Open &amp;lt;code&amp;gt;C:\Program Files\Cortec\bicRpcServer-setup&amp;lt;/code&amp;gt; in the File Explorer.&lt;br /&gt;
# Double-click &amp;lt;code&amp;gt;bicRpcServer.exe&amp;lt;/code&amp;gt;. Start it from its own folder, so that it finds &amp;lt;code&amp;gt;config.json&amp;lt;/code&amp;gt; and the DLLs next to it.&lt;br /&gt;
# A console window opens. Leave it open for the whole session; closing it stops the server.&lt;br /&gt;
# The first time the server starts, Windows may show a &amp;#039;&amp;#039;Windows Security&amp;#039;&amp;#039; firewall prompt. Click &amp;#039;&amp;#039;Allow&amp;#039;&amp;#039;. This matters only when BCI2000 runs on another computer (see [[#Remote Setup Through a Router|below]]).&lt;br /&gt;
&lt;br /&gt;
To confirm that the server started, open &amp;lt;code&amp;gt;session_logger.text&amp;lt;/code&amp;gt;. A new line ending in &amp;lt;code&amp;gt;Application construction&amp;lt;/code&amp;gt; with the current time appears at each start:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
[INFO ][2026/10/27 14:06:39:207][...BICServerApplication.cpp:64][21124] Application construction&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The server does not contact the implant at this point. It opens the external unit when BCI2000 connects.&lt;br /&gt;
&lt;br /&gt;
==Connecting BCI2000==&lt;br /&gt;
===Starting BCI2000 with RemoteBICSource===&lt;br /&gt;
BCI2000 ships three batch files that use the module. They are in &amp;lt;code&amp;gt;C:\BCI2000\batch&amp;lt;/code&amp;gt;:&lt;br /&gt;
* &amp;lt;code&amp;gt;CursorTask_RemoteBIC.bat&amp;lt;/code&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;P3Speller_RemoteBIC.bat&amp;lt;/code&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;StimulusPresentation_RemoteBIC.bat&amp;lt;/code&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Each one starts &amp;lt;code&amp;gt;RemoteBICSource&amp;lt;/code&amp;gt; as the source module and loads the parameter fragment &amp;lt;code&amp;gt;C:\BCI2000\parms\fragments\amplifiers\RemoteBIC.prm&amp;lt;/code&amp;gt;. To use the module in your own batch file, replace the source module line and load the fragment:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Start executable RemoteBICSource --local&lt;br /&gt;
...&lt;br /&gt;
Wait for Connected&lt;br /&gt;
Load parameterfile &amp;quot;../parms/fragments/amplifiers/RemoteBIC.prm&amp;quot;&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
# Make sure the server is running.&lt;br /&gt;
# Double-click one of the batch files, for example &amp;lt;code&amp;gt;StimulusPresentation_RemoteBIC.bat&amp;lt;/code&amp;gt;.&lt;br /&gt;
# Wait until the Operator window shows that all modules are connected.&lt;br /&gt;
&lt;br /&gt;
===Source Parameters===&lt;br /&gt;
Click &amp;#039;&amp;#039;Config&amp;#039;&amp;#039; and open the &amp;#039;&amp;#039;Source&amp;#039;&amp;#039; tab. The parameters specific to this module are in the &amp;#039;&amp;#039;RemoteBIC&amp;#039;&amp;#039; section.&lt;br /&gt;
 [[File:RemoteBICSourceParameters.png|600px|thumb|center|upright=2.5|Figure 1. The default source parameters for RemoteBICSource]]&lt;br /&gt;
&lt;br /&gt;
====ConnectionAddress====&lt;br /&gt;
The address and port of the BIC RPC server, written as &amp;lt;code&amp;gt;host:port&amp;lt;/code&amp;gt;. The default is &amp;lt;code&amp;gt;localhost:50051&amp;lt;/code&amp;gt;, which is correct when the server runs on the same computer. For a server on another computer, enter its IP address, for example &amp;lt;code&amp;gt;192.168.1.10:50051&amp;lt;/code&amp;gt;.&lt;br /&gt;
&lt;br /&gt;
====Amplification====&lt;br /&gt;
Amplification applied on the implant. &amp;lt;code&amp;gt;0&amp;lt;/code&amp;gt;: 57.5 dB, &amp;lt;code&amp;gt;1&amp;lt;/code&amp;gt;: 51.5 dB, &amp;lt;code&amp;gt;2&amp;lt;/code&amp;gt;: 45.5 dB, &amp;lt;code&amp;gt;3&amp;lt;/code&amp;gt;: 39.5 dB.&lt;br /&gt;
&lt;br /&gt;
====ReferenceCh====&lt;br /&gt;
List of channels used as hardware reference, counted from 1. If set to &amp;lt;code&amp;gt;auto&amp;lt;/code&amp;gt;, no reference channel is used.&lt;br /&gt;
&lt;br /&gt;
====UseGround====&lt;br /&gt;
Enable to use the ground electrode as reference.&lt;br /&gt;
&lt;br /&gt;
====SourceCh, SamplingRate, SampleBlockSize====&lt;br /&gt;
Leave these at &amp;lt;code&amp;gt;auto&amp;lt;/code&amp;gt;. The channel count and sampling rate are read from the implant. Entering a sampling rate that differs from the implant&amp;#039;s produces the error &amp;#039;&amp;#039;Set parameter SamplingRate to auto to match BIC hardware&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
====SourceChGain, SourceChOffset, ChannelNames====&lt;br /&gt;
Leave these at &amp;lt;code&amp;gt;auto&amp;lt;/code&amp;gt;. Samples arrive in microvolts regardless of the amplification, so the gain is set to 1 µV and the offset to 0. Channels are named &amp;lt;code&amp;gt;CH0&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;CH1&amp;lt;/code&amp;gt;, and so on.&lt;br /&gt;
&lt;br /&gt;
====SaveInfoFile====&lt;br /&gt;
Enable to save a text file next to the data file, named &amp;lt;code&amp;gt;..._info0.txt&amp;lt;/code&amp;gt;, containing the time stamp, amplification factor, and reference channels.&lt;br /&gt;
&lt;br /&gt;
The &amp;#039;&amp;#039;Stimulation&amp;#039;&amp;#039; tab holds the same parameters as CortecADC: &amp;lt;code&amp;gt;EnableStimulation&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;StimulationMode&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;MeasureImpedance&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;LogStimulationEvents&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;StimulationPulses&amp;lt;/code&amp;gt;, and &amp;lt;code&amp;gt;StimulationTriggers&amp;lt;/code&amp;gt;. See [[Contributions:CortecADC#Stimulation Parameters|CortecADC]] for details. &amp;lt;code&amp;gt;StimulationMode&amp;lt;/code&amp;gt; must be &amp;lt;code&amp;gt;1&amp;lt;/code&amp;gt; (Persistent Command) or &amp;lt;code&amp;gt;2&amp;lt;/code&amp;gt; (Persistent Functions).&lt;br /&gt;
&lt;br /&gt;
==Streaming Data==&lt;br /&gt;
# In the &amp;#039;&amp;#039;Storage&amp;#039;&amp;#039; tab, set &amp;lt;code&amp;gt;SubjectName&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;SubjectSession&amp;lt;/code&amp;gt;, and &amp;lt;code&amp;gt;DataDirectory&amp;lt;/code&amp;gt; as for any BCI2000 recording.&lt;br /&gt;
# Click &amp;#039;&amp;#039;Set Config&amp;#039;&amp;#039;. BCI2000 now contacts the server, the server opens the external unit, powers the implant, and starts the measurement. &amp;#039;&amp;#039;&amp;#039;This takes ten to fifteen seconds.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
# Check the Operator log. Two messages confirm the connection:&lt;br /&gt;
#* &amp;#039;&amp;#039;The following external units were discovered:&amp;#039;&amp;#039; followed by the external unit ID, type, and index.&lt;br /&gt;
#* &amp;#039;&amp;#039;The implant information for to the EU at index: 0&amp;#039;&amp;#039; followed by the device type, device ID, and firmware version.&lt;br /&gt;
# The source signal window opens and shows the implant channels. Data are now streaming from the implant, through the server, into BCI2000.&lt;br /&gt;
# Click &amp;#039;&amp;#039;Start&amp;#039;&amp;#039; to begin a run and write data to disk. Click &amp;#039;&amp;#039;Suspend&amp;#039;&amp;#039; to end the run.&lt;br /&gt;
# To finish, close BCI2000 first. On shutdown the module stops the measurement and switches off the implant power. Then close the server&amp;#039;s console window.&lt;br /&gt;
&lt;br /&gt;
On the server side, &amp;lt;code&amp;gt;session_logger.text&amp;lt;/code&amp;gt; shows the same sequence. Each line is a request from BCI2000:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Request to get external unit info received.&lt;br /&gt;
Response to get external unit info has been sent.&lt;br /&gt;
Request to get implant info received.&lt;br /&gt;
Response of implant info has been sent.&lt;br /&gt;
Request to create implant object received.&lt;br /&gt;
Response to create implant has been sent.&lt;br /&gt;
Request to get device infos received.&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
If &amp;lt;code&amp;gt;MeasureImpedance&amp;lt;/code&amp;gt; is enabled, the impedance of every channel is measured at &amp;#039;&amp;#039;Set Config&amp;#039;&amp;#039;, shown in a separate &amp;#039;&amp;#039;Cortec Impedances&amp;#039;&amp;#039; window, and saved to the info file.&lt;br /&gt;
&lt;br /&gt;
===Recorded States===&lt;br /&gt;
Besides the signal, the module records the implant&amp;#039;s telemetry as BCI2000 events: &amp;lt;code&amp;gt;ImplantTemperature&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;ImplantVoltage&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;ImplantHumidity&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;ImplantControlValue&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;ImplantPrimaryCoilCurrent&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;ImplantStimulation&amp;lt;/code&amp;gt;, &amp;lt;code&amp;gt;ImplantRfQuality&amp;lt;/code&amp;gt;, and &amp;lt;code&amp;gt;ImplantLastStimulationID&amp;lt;/code&amp;gt;. It also records the &amp;lt;code&amp;gt;ImplantLostSample&amp;lt;/code&amp;gt; stream and the &amp;lt;code&amp;gt;RequestedStimulation&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;PauseStimulation&amp;lt;/code&amp;gt; states. Their units and multipliers are listed in the &amp;lt;code&amp;gt;StateInfo&amp;lt;/code&amp;gt; parameter and explained on the [[Contributions:CortecADC#States|CortecADC]] page.&lt;br /&gt;
&lt;br /&gt;
==Remote Setup Through a Router==&lt;br /&gt;
The server and BCI2000 do not have to share a computer. In a remote setup, a small &amp;#039;&amp;#039;server computer&amp;#039;&amp;#039; stays with the implant and the external unit, and a second &amp;#039;&amp;#039;BCI2000 computer&amp;#039;&amp;#039; runs the experiment. A router connects the two. This is the arrangement used for the demonstration at the Mayo Clinic.&lt;br /&gt;
&amp;lt;!-- TODO (Nick): replace the example addresses below with the ones used at the Mayo Clinic, and add the router model and whether the link was wired or wireless. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 Implant &amp;lt;-- RF --&amp;gt; External unit&lt;br /&gt;
                         |&lt;br /&gt;
                        USB&lt;br /&gt;
                         |&lt;br /&gt;
              +---------------------+        +----------+        +---------------------+&lt;br /&gt;
              |  Server computer    |        |          |        |  BCI2000 computer   |&lt;br /&gt;
              |  bicRpcServer.exe   | &amp;lt;----&amp;gt; |  Router  | &amp;lt;----&amp;gt; |  RemoteBICSource    |&lt;br /&gt;
              |  192.168.1.10       |        |          |        |  192.168.1.20       |&lt;br /&gt;
              +---------------------+        +----------+        +---------------------+&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The addresses in this section are examples. Use the ones your router assigns.&lt;br /&gt;
&lt;br /&gt;
===Step 1: Build the Network===&lt;br /&gt;
# Use a dedicated router that is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; connected to the internet or to a hospital or university network. The data stream is not encrypted, and the server accepts any client that can reach its port.&lt;br /&gt;
# Connect both computers to the router. Use Ethernet cables where possible; a wireless link works but adds jitter and lost samples.&lt;br /&gt;
# Give the server computer a fixed address, so that it does not change between sessions. Either reserve an address for it in the router&amp;#039;s DHCP settings, or set a static IPv4 address in Windows under &amp;#039;&amp;#039;Settings → Network &amp;amp; internet → Ethernet → IP assignment → Edit&amp;#039;&amp;#039;.&lt;br /&gt;
# On the server computer, open a PowerShell window and run &amp;lt;code&amp;gt;ipconfig&amp;lt;/code&amp;gt;. Note the &amp;#039;&amp;#039;IPv4 Address&amp;#039;&amp;#039; of the adapter connected to the router. An address beginning with &amp;lt;code&amp;gt;169.254&amp;lt;/code&amp;gt; means the computer did not receive an address from the router.&lt;br /&gt;
&lt;br /&gt;
===Step 2: Configure the Server Computer===&lt;br /&gt;
# Install the BIC RPC server on the server computer and plug the external unit into it.&lt;br /&gt;
# In &amp;lt;code&amp;gt;config.json&amp;lt;/code&amp;gt;, set &amp;lt;code&amp;gt;address&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;0.0.0.0&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;port&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;50051&amp;lt;/code&amp;gt;. With &amp;lt;code&amp;gt;127.0.0.1&amp;lt;/code&amp;gt; the server would refuse connections from other computers.&lt;br /&gt;
# Allow the server through the Windows firewall. Open PowerShell with &amp;#039;&amp;#039;Run as administrator&amp;#039;&amp;#039; and run:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
New-NetFirewallRule -DisplayName &amp;quot;bicRpcServer&amp;quot; -Direction Inbound -Action Allow -Protocol TCP -LocalPort 50051 -Program &amp;quot;C:\Program Files\Cortec\bicRpcServer-setup\bicRpcServer.exe&amp;quot; -Profile Any&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
: Windows assigns a new router network the &amp;#039;&amp;#039;Public&amp;#039;&amp;#039; profile. A rule that covers only &amp;#039;&amp;#039;Private&amp;#039;&amp;#039; networks will not apply to it, which is why the command uses &amp;lt;code&amp;gt;-Profile Any&amp;lt;/code&amp;gt;. If you clicked &amp;#039;&amp;#039;Allow&amp;#039;&amp;#039; on the firewall prompt at the first start, check under &amp;#039;&amp;#039;Windows Defender Firewall → Allowed apps&amp;#039;&amp;#039; that the box for the profile in use is ticked.&lt;br /&gt;
# Start &amp;lt;code&amp;gt;bicRpcServer.exe&amp;lt;/code&amp;gt;.&lt;br /&gt;
&lt;br /&gt;
===Step 3: Test the Connection===&lt;br /&gt;
On the BCI2000 computer, open PowerShell and run:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Test-NetConnection 192.168.1.10 -Port 50051&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
The result must show &amp;lt;code&amp;gt;TcpTestSucceeded : True&amp;lt;/code&amp;gt;. If it shows &amp;lt;code&amp;gt;False&amp;lt;/code&amp;gt;, BCI2000 will not connect either. Check, in this order: that the server is running, the IP address, the firewall rule, and the cables.&lt;br /&gt;
&lt;br /&gt;
===Step 4: Connect BCI2000===&lt;br /&gt;
# On the BCI2000 computer, start a RemoteBIC batch file.&lt;br /&gt;
# Click &amp;#039;&amp;#039;Config&amp;#039;&amp;#039;, open the &amp;#039;&amp;#039;Source&amp;#039;&amp;#039; tab, and set &amp;lt;code&amp;gt;ConnectionAddress&amp;lt;/code&amp;gt; to the server computer&amp;#039;s address and port: &amp;lt;code&amp;gt;192.168.1.10:50051&amp;lt;/code&amp;gt;.&lt;br /&gt;
# Click &amp;#039;&amp;#039;Set Config&amp;#039;&amp;#039; and continue as described under [[#Streaming Data|Streaming Data]].&lt;br /&gt;
&lt;br /&gt;
To avoid typing the address at every start, save the configuration to a parameter file with &amp;#039;&amp;#039;Save Parameters&amp;#039;&amp;#039;, or add a line to your batch file after the parameter files are loaded:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Set parameter ConnectionAddress 192.168.1.10:50051&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===Notes on Remote Operation===&lt;br /&gt;
* The BCI2000 computer needs neither the CorTec API nor the USB driver. Only the server computer talks to the hardware.&lt;br /&gt;
* Data files are written on the BCI2000 computer. The server computer keeps only its two log files.&lt;br /&gt;
* Someone must be able to start the server on the server computer, either in person or through remote desktop software.&lt;br /&gt;
* If the network connection drops during a run, samples stop arriving and the signal display goes blank. Suspend the run, restore the connection, and click &amp;#039;&amp;#039;Set Config&amp;#039;&amp;#039; again.&lt;br /&gt;
* Stimulation commands are uploaded to the implant at &amp;#039;&amp;#039;Set Config&amp;#039;&amp;#039; and only triggered over the network, so stimulation latency includes the network delay. Measure it for your own setup using the &amp;lt;code&amp;gt;RequestedStimulation&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;ImplantStimulation&amp;lt;/code&amp;gt; states, as described on the [[Contributions:CortecADC#RequestedStimulation|CortecADC]] page.&lt;br /&gt;
&lt;br /&gt;
==Troubleshooting==&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symptom !! Likely cause !! What to do&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;Set Config&amp;#039;&amp;#039; fails with an error starting with &amp;lt;code&amp;gt;RemoteBIC:&amp;lt;/code&amp;gt;&lt;br /&gt;
|BCI2000 cannot reach the server.&lt;br /&gt;
|Check that the server is running and that &amp;lt;code&amp;gt;ConnectionAddress&amp;lt;/code&amp;gt; has the right address and port. For a remote server, run the &amp;lt;code&amp;gt;Test-NetConnection&amp;lt;/code&amp;gt; test above.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;Could not create implant&amp;#039;&amp;#039;&lt;br /&gt;
|The server is reachable but cannot open the implant.&lt;br /&gt;
|Check that the external unit is plugged in, the head piece sits over the implant, and no other program is using the device. Try a different USB port.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;Set parameter SamplingRate to auto to match BIC hardware&amp;#039;&amp;#039;&lt;br /&gt;
|A sampling rate was entered by hand or loaded from another parameter file.&lt;br /&gt;
|Set &amp;lt;code&amp;gt;SamplingRate&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;auto&amp;lt;/code&amp;gt;, or load &amp;lt;code&amp;gt;RemoteBIC.prm&amp;lt;/code&amp;gt; last.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;Volatile stimulation mode is not available with RemoteBIC&amp;#039;&amp;#039;&lt;br /&gt;
|&amp;lt;code&amp;gt;StimulationMode&amp;lt;/code&amp;gt; is &amp;lt;code&amp;gt;0&amp;lt;/code&amp;gt;.&lt;br /&gt;
|Set &amp;lt;code&amp;gt;StimulationMode&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;1&amp;lt;/code&amp;gt; or &amp;lt;code&amp;gt;2&amp;lt;/code&amp;gt;.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;#039;&amp;#039;ReferenceCh entry ... out of range&amp;#039;&amp;#039;&lt;br /&gt;
|A reference channel is 0 or larger than the channel count.&lt;br /&gt;
|Reference channels are counted from 1.&lt;br /&gt;
|-&lt;br /&gt;
|The signal display is blank during a run&lt;br /&gt;
|No samples have arrived for more than a second.&lt;br /&gt;
|The network link or the RF link to the implant is interrupted. Check the head piece position and the network, then click &amp;#039;&amp;#039;Set Config&amp;#039;&amp;#039; again.&lt;br /&gt;
|-&lt;br /&gt;
|Many lost samples in &amp;lt;code&amp;gt;ImplantLostSample&amp;lt;/code&amp;gt;&lt;br /&gt;
|Poor coupling between head piece and implant.&lt;br /&gt;
|Reposition the head piece and watch &amp;lt;code&amp;gt;ImplantRfQuality&amp;lt;/code&amp;gt; and &amp;lt;code&amp;gt;ImplantControlValue&amp;lt;/code&amp;gt;.&lt;br /&gt;
|-&lt;br /&gt;
|The server window closes immediately&lt;br /&gt;
|The server cannot find &amp;lt;code&amp;gt;config.json&amp;lt;/code&amp;gt;, or the file is not valid JSON.&lt;br /&gt;
|Start the server from its own folder and check the file for missing quotes or commas.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;session_logger.text&amp;lt;/code&amp;gt; does not change&lt;br /&gt;
|The server cannot write to its folder, or logging is off.&lt;br /&gt;
|Run the server as administrator or grant &amp;#039;&amp;#039;Modify&amp;#039;&amp;#039; permission on the folder, and set &amp;lt;code&amp;gt;enableLogging&amp;lt;/code&amp;gt; to &amp;lt;code&amp;gt;true&amp;lt;/code&amp;gt;.&lt;br /&gt;
|-&lt;br /&gt;
|&amp;lt;code&amp;gt;RemoteBICSource.exe&amp;lt;/code&amp;gt; is missing from &amp;lt;code&amp;gt;prog&amp;lt;/code&amp;gt;&lt;br /&gt;
|BCI2000 was built without the module.&lt;br /&gt;
|Enable &amp;lt;code&amp;gt;BUILD_REMOTEBIC_SOURCE&amp;lt;/code&amp;gt; in CMake and rebuild.&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==See also==&lt;br /&gt;
[[Contributions:CortecADC]], [[CortecExperience]], [[User Reference:Filters]], [[Contributions:ADCs]]&lt;br /&gt;